測試項目 | EV-ECD01控制系統在HGP上加減速特性測試(企業標準) | ||||||
測試人員 | 張曰國 | 測試日期 | 2008/10/7 | ||||
運行樓層 | 載荷 | 平均加速度m/s2 | 平均減速度m/s2 | 垂直振動 | 水平振動(X) cm/s2 | 水平振動(Y) cm/s2 | 結果判定 |
cm/s2 | |||||||
1F→5F | 0% | 0.622 | 0.61 | 11.2 | 15.2 | 16 | NG |
5F→1F | 0.619 | 0.611 | 15.6 | 14.4 | 13.6 | OK | |
1F→3F | 0.624 | 0.61 | 13.2 | 17.2 | 12.4 | NG | |
3F→1F | 0.616 | 0.615 | 18 | 12.8 | 8 | OK | |
1F→5F | 25% | 0.624 | 0.612 | 14 | 18 | 11.6 | NG |
5F→1F | 0.618 | 0.616 | 20.8 | 13.2 | 10.4 | NG | |
1F→3F | 0.625 | 0.61 | 12.8 | 9.2 | 8 | OK | |
3F→1F | 0.618 | 0.619 | 9.6 | 9.6 | 11.6 | OK | |
1F→5F | 50% | 0.618 | 0.61 | 12 | 16.8 | 9.6 | NG |
5F→1F | 0.617 | 0.618 | 15.2 | 14.4 | 9.6 | OK | |
1F→3F | 0.625 | 0.611 | 15.2 | 8.8 | 8 | OK | |
3F→1F | 0.62 | 0.617 | 8.4 | 9.6 | 5.2 | OK | |
1F→5F | 75% | 0.625 | 0.617 | 10.4 | 13.6 | 8 | OK |
5F→1F | 0.618 | 0.618 | 9.2 | 12.8 | 7.6 | OK | |
1F→3F | 0.63 | 0.613 | 10.8 | 7.6 | 7.2 | OK | |
3F→1F | 0.618 | 0.623 | 10.4 | 5.6 | 4.8 | OK | |
1F→5F | 100% | 0.629 | 616 | 8.8 | 10.8 | 6.4 | OK |
5F→1F | 0.62 | 0.626 | 8.8 | 10.8 | 6.4 | OK | |
1F→3F | 0.628 | 0.619 | 9.2 | 6.4 | 5.6 | OK | |
3F→1F | 0.62 | 0.624 | 6.8 | 6.4 | 4 | OK | |